Analysis
XPS/UPS Escalab 250Xi, XPS K-Alpha
|
- Quantitative chemical and molecular surface spectroscopy (< 10 nm)
- Chemical mapping 2D (3 μm lateral resolution)
- Polymers depth profiling (deepness)
- Ar+ ions
- Ar+ clusters sources (organic materials profiling)
- Typical depth of analysis 1-10 nm. Typical lateral resolution 0.5-3 µm
- UV photoemission spectroscopy – valence balance
|
![escalab-xps.png](https://www.poledenamur.be/en/platforms/pictures/escalab-xps-1.png/@@images/ac709cbd-04a1-4195-9500-7321b3293085.png) |
ION BEAM ANALYSIS (IBA)
|
Tandetron Linear Accelerator (ALTAÏS) – Characterization
- Quantitative (sensitivity ~10 wt.ppm)
- Non-destructive
- Model-free
- Depth profiling (depth resolution ~1-10 nm)
- 2D elemental maps (lateral resolution ~1 µm), microprobe (µPIXE available)
- H depth profiling capability
|
![Ion Beam Analysis.png](https://www.poledenamur.be/en/platforms/pictures/ion-beam-analysis.png/@@images/dec31d1b-21ae-40c1-9190-ec85ac074c3d.png) |
ToF-SIMS IV, IONTOF
|
- Beam line for ion implantation
- Molecular surface spectroscopy
- Semi quantitative (with standards)
- Very sensitive
- Chemical mapping
- Profiling (deepness)
|
![ToF-SIMS.png](https://www.poledenamur.be/en/platforms/pictures/tof-sims.png/@@images/f61e7b57-e1d4-405b-af9e-b56f9d85fd7c.png) |
CELL IRRADIATION
|
Tandetron Linear Accelerator (ALTAÏS) – Irradiation: Large and uniform beam (~ 0.5cm²)
- Radiobiology station (cells irradiation)
- Vacuum & non vacuum beam line for radiobiology
- Irradiation station
|
![irradiation station ok.png](https://www.poledenamur.be/en/platforms/pictures/irradiation-station-ok.png/@@images/ce7b3cc8-20dc-4f83-8493-7f9475c597b4.png)
|
Synthesis
ION BEAM IMPLANTATION
|
- Beam line for ion implantation
- Vacuum & non vacuum beam line for atomic and nuclear spectroscopies
- UHV and very low noise beam lines for surface and interface analysis
- Non-destructive quantitative characterization
- Composition and thickness of thin films (a few microns)
- Adaptable geometry measurement
- Polymers and biological samples analysis
- Sample size: maximum 20 mm in diameter
|
![IBA.png](https://www.poledenamur.be/en/platforms/pictures/iba-1.png/@@images/e405494b-6602-46a5-9aee-03f62776686d.png)
|
PLASMA-BASED SURFACE TREATMENT
|
Plasma sputtering: 4 chambers for plasma sputtering (DC, RF and AC)
- Plasma functionalization
- Thin films deposition
PECVD deposition: 4 chambers for PECVD deposition and functionalisation
|
![PECVD.png](https://www.poledenamur.be/en/platforms/pictures/pecvd-1.png/@@images/f2e0eaab-b754-4d9b-8301-1622c6c6f308.png)
|